The over/under pressure VSP 380 safety valve has been engineered in order to protect silos and hoppers against occasional
over -and under- pressures which can be generated by :
The VSP 380 has been designed to operate only on the roof of the silo.
Painted galvanized steel or stainless steel 304 L execution
Setting at :
Over-pressure : 500 mm H2O – Under-pressure : 20 mm H2O
Maximum pressures :
Over-pressure : 600 mm H2O – Under-pressure : 120 mm H2O
Pression Over pressure – Presion – überdruck | Dépression Under pressure – Depresion – Unterdruck | ||
---|---|---|---|
X mm | mm H2O | Y mm | mm H2O |
65 | 600 | 75 | 120 |
75 | 500 | 85 | 90 |
85 | 400 | 44 | 50 |
90 | 350 | 70 | 20 |